AngLure™ Field Test Instructions
Thank you for participating in the AngLure™ Field Test Program.
Your feedback is an important part of bringing the AngLure Lighting System to market. These instructions will help you get the best experience from your prototype and provide useful feedback from real fishing conditions.
Prototype Notice
Each field test AngLure™ Lighting System is a hand assembled field test prototype. Minor cosmetic imperfections are normal and do not affect performance.
This manual applies to the current AngLure™ field test prototype. The product design, features, operation, specifications, accessories, and instructions may change as the AngLure™ is evaluated and refined for commercial production.
AngLure™ Lighting System
User Manual
Field Test Edition V 1.0

Table of Contents
4. Turning the AngLure™ On and Off
1. Safety and Responsible Use
- Use the AngLure™ only for its intended purposes as a fishing light or portable light.
- Keep the AngLure™, activation magnet, color filters, and other small parts out of reach of children and pets. This product is not a toy. Do not place the product or any accessory in the mouth. Seek immediate medical attention if the magnet is swallowed. Swallowed magnets can cause serious internal injuries.
- Do not expose the AngLure™ to fire, extreme heat, or prolonged direct sunlight. Do not leave it in a hot vehicle.
- Do not crush, puncture, modify, or attempt to disassemble the AngLure™.
- Inspect the AngLure™ before each use. Do not use it if the housing, charging contacts, charger, or cord appear damaged, loose, cracked, or deformed.
- Charge only with the supplied AngLure™ charging dock and cable connected to a standard 5 volt USB power source. Do not connect the charger to a higher voltage source or use a fast charger, Quick Charge adapter, USB Power Delivery adapter, or other power source that may supply more than 5 volts.
- Charge only in a dry location. Make certain the AngLure™ and its charging contacts are completely dry before placing it in the charging dock. Do not place the AngLure™ or charging dock in water while connected to power.
- Rinse the AngLure™ with fresh water after use. Allow it to dry completely before charging or storage.
- If the AngLure™ becomes unusually hot, emits smoke or an unusual odor, appears swollen or damaged, or if the red FAULT indicator illuminates, disconnect power if it is safe to do so and discontinue use. If it can be moved safely, place it outdoors in an open area away from people, pets, structures, vehicles, and anything that can burn. Do not handle the unit if it is smoking, extremely hot, or actively burning. Rechargeable lithium battery products can present overheating, fire, and burn hazards when damaged or improperly charged.
- Do not dispose of the AngLure™ in a fire. Follow applicable local requirements for disposal of products containing rechargeable lithium batteries.
- Use the AngLure™ responsibly and in a manner that does not endanger people, pets, wildlife, boats, equipment, or other property.
- Follow all applicable local, state, and federal fishing laws and regulations. The user is responsible for determining whether illuminated fishing devices are permitted in the waters being fished. Fishing requirements may vary by state and by specific body of water.
2. Package Contents
- AngLure™
- AngLure™ Charger
- Charging Cord (USB, 5V only)
- Floating Magnetic Keychain
- Extra Cap
- Color Filters
- Fiber Bundle
- Extra Fibers
3. Product Overview
The AngLure™ Lighting System is a compact, rechargeable light designed to attach directly to a fishing line ahead of the hook, lure, or bait. A white LED inside the sealed housing sends light through flexible fiber optic strands, producing bright points of light at the strand ends with a softer glow visible along portions of the strands. This allows existing lures and bait presentations to be illuminated without modifying the lure itself.
The AngLure™ is designed for use in both fresh water and salt water for depths of up to 300 feet. A typical full charge provides approximately 4 to 6 hours of operation, depending on conditions and use. Optional color filters can be installed to change the color of the emitted light, allowing the user to experiment with different presentations, water conditions, and target species.
A tunnel through the side of the housing allows the fishing line to pass directly through the unit. Stops placed immediately before and after the tunnel hold the AngLure™ in position while fishing. The unit is turned on and off with the supplied activation magnet, eliminating the need for an exposed mechanical switch.
The AngLure™ is recharged using the supplied charging dock and a standard 5 volt USB power source. The charger provides visible status indicators for ready, charging, fully charged, and fault conditions.
Although designed primarily as a fishing light, the AngLure™ may also be used as a compact portable light while camping, boating, or during other low light activities.

4. Turning the AngLure™ On and Off
The AngLure™ uses an internal magnetic switch to activate and deactivate the light. The approximate location is shown below.

AngLure™ Switch Float
The AngLure™ comes with a fish shaped float containing powerful magnets Shown below. These magnets can be seen directly below the “L” in the Anglure logo.

To activate/deactivate the AngLure™, hold the switch float vertically with the magnets close to or touching the side of the AngLure™. Slowly move the switch float up and down the side of the AngLure™ close to the magnetic switch (see below). When the magnets pass the switch it the AngLure™ will turn on or off. Verify operation by observing the illuminated fiber optic strands.

5. Charging Instructions
The AngLure™ is supplied with a charging dock and USB cable.
- Ensure the AngLure™ is completely dry.
- Connect the charging dock to a 5 volt USB power source.
- Insert the AngLure™ into the charging dock, it will only fit one way
- If the AngLure™ light comes on when charging, turn it off to allow for full charging.
- The charging contacts automatically align with the charging dock.
- Allow the AngLure™ to charge fully before use.
Typical charging time is 2 to 3 hours.
The AngLure™ may remain in the charger after charging is complete without damage.
Do NOT remove the AngLure™ from the charger by pulling on the fibers.

6. LED Indicators
Power Indicator (Green)
Solid green indicates power to the charger.
Charge Indicator (Orange)
Slow Flash – No AngLure™ detected.
Solid On – Charging in progress.
Fast Flash – Charging complete.
Fault Indicator (Red)
Off – Normal operation.
On – Battery or charging fault detected.
If the FAULT indicator is illuminated disconnect power if it is safe to do so and discontinue use. If it can be moved safely, place it outdoors in an open area away from people, pets, structures, vehicles, and anything that can burn. Do not handle the unit if it is smoking, extremely hot, or actively burning. Rechargeable lithium battery products can present overheating, fire, and burn hazards when damaged or improperly charged.
7. Installation and Rigging
Removing and Replacing the Cap
The AngLure™ cap uses a twist lock design similar to a standard child resistant pill bottle cap.
To remove the cap, press down firmly while turning it counterclockwise. Once it unlocks, lift the cap off.
To replace the cap, position it on the AngLure™, press down firmly, and turn it clockwise until you hear or feel a click.
Confirm that the cap is fully seated and secure before use.
Changing the Fiber Assembly
To change the fibers, turn the AngLure™ off before changing the fibers.
Remove the cap by pressing down and turning it counterclockwise.
Lift the cap away from the body.
Carefully remove the existing fiber assembly from the front of the AngLure™.
Pull on the holder rather than the fibers.
Position the replacement fiber assembly in the same orientation and press it fully into place.
Make certain the holder is seated evenly and that no fibers are trapped between the cap and the housing.
Replace the cap by pressing down and turning it clockwise until you hear or feel a click.
Confirm that the cap and fiber assembly are secure before using the AngLure™.
Changing the Light Color Filter
Turn the AngLure™ off before changing the color filter.
Remove the cap by pressing down and turning it counterclockwise.
Select the desired color filter disk. Each disk has a clear protective film on both sides. Remove the film from both sides before installation.
Place the filter disk between the LED and the fiber assembly. Make certain the disk lies flat and is centered over the LED.
Replace the cap by pressing down and turning it clockwise until you hear or feel a click. Confirm that the cap is fully seated and secure before use.
Store unused filter disks in a clean, dry location to prevent scratches, fingerprints, and dirt from reducing light transmission.
Installation of the AngLure™
The AngLure™ is installed directly on the fishing line ahead of the lure, bait, or hook.
- Thread the fishing line through the Line Tunnel.
- Install a line stop ahead of the AngLure™.
- Install a second line stop behind the AngLure™.
- Attach the lure, bait, or hook.
The line stops prevent the AngLure™ from moving along the line during use. Location of the AngLure™ can be varied as desired.

The fiber optic strands may be trimmed to the desired length. They may also be reshaped by gradually heating them to approximately 200°F, bending them into the desired position, and holding them in place until completely cool. Test the process on a small section first. Avoid open flames, direct contact with heating elements, and overheating, which may damage or deform the fibers.
8. Care and Maintenance
Rinse the AngLure™ with fresh water after each use, especially after use in salt water. Remove any dirt, sand, vegetation, or other debris from the housing, fiber optic strands, line tunnel, and charging contacts.
Allow the AngLure™ to dry completely before charging or storage. Do not place the AngLure™ in the charging dock while the housing or charging contacts are wet.
Wipe the housing and charging contacts with a soft, clean cloth. Do not use abrasive cleaners, harsh chemicals, solvents, or metal tools that could scratch the housing or damage the charging contacts.
Inspect the AngLure™ before and after each use. Check the housing, charging contacts, fiber optic strands, charging dock, and cord for cracks, looseness, deformation, corrosion, or other damage. Discontinue use if damage is found.
The fiber optic strands may be trimmed to the desired length using sharp scissors or suitable cutters. Make clean, straight cuts to preserve the appearance of the illuminated ends.
The fiber optic strands may also be reshaped by gradually heating them to approximately 200°F, bending them into the desired position, and holding them in place until completely cool. Test the process on a small section first. Avoid open flames, direct contact with heating elements, and overheating, which may cloud, flatten, melt, or otherwise damage the fibers.
Do not pull sharply on the fiber optic strands or use them to carry, lift, or retrieve the AngLure™.
Store the AngLure™ in the off position in a cool, dry location away from direct sunlight, extreme heat, and combustible materials. Do not leave it in a hot vehicle.
Recharge the AngLure™ periodically during extended storage. Inspect the unit before charging if it has not been used for an extended period.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| AngLure™ will not turn on. | Battery discharged. | Recharge the AngLure™. |
| Magnet was moved too quickly or too far from the switch area. | Hold the AngLure™ Switch Float close to the side of the housing and move it slowly up and down near the magnetic switch location. | |
| AngLure™ appears completely unresponsive. | Internal battery protection may have activated after the battery was fully discharged. | Recharge the AngLure™. |
| AngLure™ does not charge. | Charging contacts are wet, dirty, or not making proper contact. | Remove the AngLure™ from the dock. Clean and dry the charging contacts, then reinstall it. |
| Incorrect USB power source. | Use the supplied charging dock and cable with a standard 5 volt USB power source. | |
| Red FAULT indicator is illuminated. | Battery or charging fault. | Disconnect power, remove the AngLure™ from the charging dock, and discontinue use. If it can be moved safely, place it outdoors in an open area away from people, pets, structures, vehicles, and anything that can burn. |
| AngLure™ turns on while charging. | while charging The unit was left on until the battery protection circuit shut it down, and the magnetic switch retained the on setting. | Use the AngLure™ Switch Float to turn the unit off before continuing to charge. |
| Runtime is shorter than expected. | Battery was not fully charged or temperature is affecting the runtime. | Recharge the AngLure™. |
| Fiber optic strands appear dim. | Strand ends are dirty, damaged, or obstructed. | Clean the fibers and inspect them for damage. Trim damaged ends if necessary. |
| Battery was not fully charged or temperature is affecting the runtime. | Recharge the AngLure™. | |
| AngLure™ becomes unusually hot, emits smoke or an unusual odor, or appears swollen or damaged. | Possible battery or electrical fault. | Disconnect power if it is safe to do so and discontinue use. If it can be moved safely, place it outdoors in an open area away from people, pets, structures, vehicles, and anything that can burn. |
Any other problems? Email us at fieldtest@anglure.net
10. Specifications
| Specification | Details |
|---|---|
| Product | AngLure™ Lighting System |
| Light Source | Internal 5 mm white LED |
| Optical System | Flexible PMMA fiber optic light guides |
| Light Output | Bright points of light at the fiber ends with softer light visible along portions of the fibers |
| Activation | Magnetic on and off control using the supplied AngLure™ Switch Float |
| Power Source | Internal rechargeable lithium battery system |
| Typical Runtime | Approximately 4 to 6 hours per full charge |
| Typical Charge Time | Approximately 2 to 3 hours |
| Charging Method | Supplied AngLure™ charging dock |
| Charger Input | Standard 5 volt USB power source |
| Charge Indicators | Orange LED for ready, charging, and fully charged status |
| Fault Indicator | Red LED for battery or charging faults |
| Water Use | Fresh water and salt water |
| Depth Rating | Approximately 300 feet |
| Line Attachment | Fishing line passes through the side tunnel and is secured with stops before and after the unit |
| Recommended Position | Ahead of the hook, lure, or bait |
| Color Options | Replaceable color filters alter the emitted light color |
| Fiber Adjustment | Fibers may be trimmed or heat shaped as needed |
| Housing | Sealed field test prototype housing |
| Additional Uses | May also be used as a compact portable light for camping, boating |
Specifications are based on the current field test prototype and may change as the product is refined for commercial production.